Pneumatic data of the connection modules, Dimensioning of the connection modules – Burkert Type 8644 User Manual
Page 19
19
TechnicalData
6.4.
pneumatic data of the connection modules
Permitted temperature
(storage / transport)
-20 ... +60° C
Permitted air humidity
(operation)
75 % on average, 85 % occasionally
CAuTIoN!
In the range of 0 – +55 °C take suitable measures against increased air humidity (> 85 %).
Slight condensation may occasionally occur on the external housing for a brief period, e.g. if the feed of a
vehicle is brought into a closed room.
Permitted air pressure
operation:
80 kPa to 106 kPa (up to 2,000 m above sea level)
Storage / transport:
70 kPa to 106 kPa (up to 3,000 m above sea level)
Protection class
Class 3 in accordance with VDE 106, IEC 60536
Protection class
IP20 in accordance with IEC 60529
6.4.1.
dimensioning of the connection modules
me02 left
me03 left
me02 middle
me03 middle
housing dimensions
(width x height x depth)
67 x 73 x 125 mm
(including catch
hook)
80 x 95 x 142 mm
(including catch
hook)
50 x 71 x 119 mm
(including catch
hook)
62 x 93 x 142 mm
(including catch
hook)
Weight
220 g
400 g
118 g
335 g
me02 right
me03 right
housing dimensions
(width x height x depth)
51 x 73 x 119 mm
61 x 95 x 142 mm
Weight
220 g
390 g
english
Type 8644