Burkert Type 8644 User Manual
Page 18
18
TechnicalData
ambient temperature
0 ... +55 °C
0 ... +55 °C
0 ... +55 °C
Operating voltage
24 V / DC, -15 % / +20 % tolerance**,
Residual ripple for field bus interface 5 %
* Power reduction (in the module)
** For the Ex-version maximum +10 %
*** The following restrictions apply to the power supply tolerances of the entire system (see Technical Data of the
entire system): Valve type: 0460 ± 10 %
add-on dimension
16.5 mm
Operating principle
Valve
C/D (3/2-way)
Type 6526
L/N (5/3-way)
Type 0461***
Operating principle
Valve
H (5/2-way)
Type 6527
H (5/2-impulse)
Type 0461
flow-rate
700 l/min
500 l/min
pressure range
(with p shut-off)
2 ... 10 bar
2.5 ... 7 bar
Output
1 W
2 W
2 x 1 W
current before
power reduction
42 mA
85 mA
41 mA
current after
power reduction
33 mA
52 mA
-
Valve locations (max.)
32
24
electrical modules
2-fold, 3-fold*, 4-fold
2-fold bistable
pneumatic modules
2-fold, 3-fold*, 4-fold
2-fold bistable
ambient temperature
0 ... +55° C
0 ... +55° C
Operating voltage
24 V / DC, -15 % / +20 % tolerance**,
Residual ripple for field bus interface 5 %
* 3 x 10 mm valves for add-on dimension of 16.5
** For the Ex-version maximum +10 %
*** The following restrictions apply to the power supply tolerances of the entire system (see Technical Data of the
entire system): Valve type: 0461 ± 10 %
interface (prOfiBus)
PROFIBUS
Copper line (RS-485), connected via PROFIBUS plug,
supply isolated, shielding connected galvanically to the functional earth
Recommended cable lengths
see PROFIBUS system data
english
Type 8644