Technical data of the valve block – Burkert Type 8644 User Manual
Page 17
17
TechnicalData
max. power consumption
Logic current
I_Log = I_Log_FBKN + ΣI_Module
I_Log
Power consumption in the logic area
I_Log_FBKN
Proportionate current in the field bus node ET200S max. 150 mA
I_Module
Proportionate current in the logic area of the electronic base modules
max 10 mA each
field bus node
see Siemens handbook
The permitted ambient temperature depends on the modules used. The most critical module is essential
during assembly.
Module with: Valve type: 6524, 6525, 6526, 6527
0 ... +55° C
Module with: Valve type: 0460, 0461
0 ... +50° C
6.3.
Technical data of the valve block
Nominal operating mode
Long-term operation (100 % ED)
Protection class (in terminal design) IP20
Protection class
3 in accordance with VDE 0580
Total current
depends on electrical connection technology, expansion stage and control
add-on dimension
11 mm
Operating principle
Valve
C/D (3/2-way)
Type 6524
2XC (2 x 3/2-way)
Type 6524
L/N (5/3-way)
Type 0460***
Operating principle
Valve
H (5/2-way)
Type 6525
-
H (5/2-impulse)
Type 0460
flow-rate
300 l/min
300 l/min
200 l/min
pressure range
(with p shut-off)
2.5 ... 7 bar
5 – 7 bar
2.5 ... 7 bar
2.5 ... 7 bar
Output
1 W
*
2 x 1 W
with power reduction
2 x 0.9 W
current before
power reduction
43 mA
2 x 43 mA
41 mA
current after
power reduction
28 mA
2 x 18 mA
-
Valve locations (max.)
64
32
32
electrical modules
2-fold, 4-fold
monostable
2-fold 2 x monostable
2-fold bistable
pneumatic modules
2-fold
2-fold bistable
2-fold bistable
english
Type 8644