beautypg.com

Burkert Type 8643 User Manual

Page 33

background image

33

Configuring the network

abs. index Variable

Data type

storage

length

access

40

IDENT_NUMBER

Unsigned8

S

1

r/w

Assignments of the standard parameters

Table 6:

All parameters of the physical block are acyclic!

Parameter structure of the bit string DIAgnOSIS

Bit

notation

Description

*

4

DIA_MEM_CHKSUM

Storage checksum error

R

10

DIA_CONF_INVAL

Configuration not valid

R

11

DIA_WARMSTART

Repeated start request
(warm start request)

A

12

DIA_COLDSTART

Restart request (cold start
request)

A

Diagnosis of the parameter coding of the Physical Block

Table 7:

Coding of the diagnosis parameters

Values of the diagnosis bits:

0 = not set
1 = set
* = display class:
r = display is active for as long as the reason of the message is available.
a = display is automatically reset after the read process.

The standard parameter View Object

rel. index

Variable

View_1

View_2

View_3

View_4

1

ST_REV

2

2

TAG_DESCRIPTION

3

STRATEGY

4

ALERT_KEY

5

TARGET_MODUS

6

MODUS _BLK

3

7

ALARM_SUM

8

View Object of the standard parameters

Table 8:

english

Type 8643 PA