System Description

Designation

Values

Max. power requirement

Bus voltage

Power consumption of bus

200 mA (17 V)
140 mA (24 V)
110 mA (32 V)

9 ... 32 V DC

12 mA /17 mA FDE

power supply voltage
2-wire version

Max. power requirement

Bus voltage

320 mA (17 V)
220 mA (24 V)
160 mA (32 V)

17 ... 32 V DC

inputs

8, intrinsically safe, NAMUR
(in accordance with EN 60947-5-6)

outputs

Outputs for pilot valves
min. switching current
min. holding current
Internal resistance
Off-load voltage

4, intrinsically safe


30 mA

1)

15 mA
330 ohm
24 V

1)

Power reduction to holding current after minimum 50 ms.

Designation

Values

Electrical connections for inputs and outputs

Screw terminals (up to 2.5 mm²)

Field bus interface
4-wire version
Ignition protection type
Electrical connection

2-wire version
Ignition protection type

Communication in accordance with IEC 1158-2

in accordance with FISCO
EEx i
4 screw terminals bus (up to 2.5 mm²)
3 screw terminals shield
(1x directly and 2x capacitively earthed)


EEx e

Auxiliary supply

Ignition protection type
Electrical connection

For 4-wire version only

Increased safety EEX e
4 screw terminals (up to 2.5 mm²)

Device key (see rating plate)

2-wire version (polyester housing)
2-wire version (aluminium housing)
4-wire version (polyester housing)
4-wire version (aluminium housing)

8643-2-PO-XX-X-XXX
8643-2-AL-XX-X-XXX
8643-4-PO-XX-X-XXX
8643-2-AL-XX-X-XXX

The cable resistance to the sensors and actuators may be max. 20

Ω.

The Power I/O Box Type 8643 may be supplied with low safety voltage in accordance with VDE 0631 only.

english

Type 8643 PA