Using the function

Automap, the input and output data of the devices in the Scanlist can be assigned to

the process map of the DeviceNet Master/Scanner.

In our example, the allocation is as shown in the illustration. For example, the input process values of
the TOP Control on/off with the address 4 are assigned to the internal addresses of the scanner as
follows:

Status sensor (repeater) S1: I:1.2.0 (Bit 0 of I:1.2)

Status sensor (repeater) S2: I:1.2.1 (Bit 1 of I:1.2)

Status sensor (repeater) S3: I:1.2.2 (Bit 2 of I:1.2)

Thus if the status of sensor S1 of the TOP Control on/off with the address 4 is to be read out from a
control program, this is done via an access to I:1.2.0.

Setting up the process map (mapping)