Operation Manual of P T Z Dome Camera
26
3. Description of “Line-Scanning” function:
¾
Dome device will auto line-scan between two specified points.
¾
User can set the start point by “52+SHOT+ON” and end point by “53+SHOT+ON”.
¾
Line scanning speed set: user keep a manual line scan speed three seconds above,
then through“51+SHOT+ACK” to save the speed as line scan speed,
use“52+SHOT+ACK” to enable the line scan.
¾
Dwell time of line-scanning between “starting point” and “ending point” is 2 seconds.
4. Intelligent manually pan continuous scan:
¾
When user use joystick for pan scan monitoring, keep manually 3 seconds, then
press“101+SHOT+ACK”, the dome can go on with the scan speed and monitor