8 - errors, Error n° guard open – CEMB USA C75 (A) User Manual
Page 30

I 0202 - 30
GB
8 - ERRORS
ERROR
MEANING
1
No rotation signal. Could be due to a faulty position transducer, or to the
motor failing to start, or to something preventing the wheel from turning.
2
During the measurement spins, wheel speed had dropped below 60
r.p.m. Check encoder functioning (see
To check the encoder)
and repeat the launch.
3
Error in the mathematical calculations, most probably caused by incorrect
carrying out of the self-calibration. Repeat the self-calibration. Wheel
unbalance too high.
4
Motor turning in opposite direction.
5
Guard open before start of spin.
7/8/9
Fault in the machine setup parameters.
Check for correctness of the basic setup parameters and repeat the
machine
calibration.
Contact
Technical
Service.
11
Speed too high for the measurement.
12/13/14
Overfl ow of counters used for the measurement. Check encoder functio
ning
(see
To check the encoder). Contact Technical Service.
15/16/17/18
Contact Technical Service.
20
Wheel stopped before having positioned it.
30
Error in clock control on the screen.
40 ÷ 53
Error in control of eccentricity measurement graphs
CAUTION
Error N°
Guard open