beautypg.com

8 - errors, Error n° guard open – CEMB USA C75 (A) User Manual

Page 30

background image

I 0202 - 30

GB

8 - ERRORS

ERROR

MEANING

1

No rotation signal. Could be due to a faulty position transducer, or to the

motor failing to start, or to something preventing the wheel from turning.

2

During the measurement spins, wheel speed had dropped below 60

r.p.m. Check encoder functioning (see

To check the encoder)

and repeat the launch.

3

Error in the mathematical calculations, most probably caused by incorrect

carrying out of the self-calibration. Repeat the self-calibration. Wheel

unbalance too high.

4

Motor turning in opposite direction.

5

Guard open before start of spin.

7/8/9

Fault in the machine setup parameters.

Check for correctness of the basic setup parameters and repeat the

machine

calibration.

Contact

Technical

Service.

11

Speed too high for the measurement.

12/13/14

Overfl ow of counters used for the measurement. Check encoder functio

ning

(see

To check the encoder). Contact Technical Service.

15/16/17/18

Contact Technical Service.

20

Wheel stopped before having positioned it.

30

Error in clock control on the screen.

40 ÷ 53

Error in control of eccentricity measurement graphs

CAUTION

Error N°

Guard open