I 0202 - 25

GB

N.B.:

If the fi rst harmonic value is higher than the limit indicated by setup parameters (see First harmonic

limit), at the end of the eccentricity measurement, the following window appears:

In this case, it is advisable to rotate the tyre on the rim by 180° in order to reduce the eccentricity
value measured.

For more detailed information, press pushbutton

.

“Note for models fi tting 42” wheelguard: eccentricity measure is valid for tyre with max. 1000 mm Ø”

Before balancing the wheel, it is advisable to rotate
the tyre on the rim by 180° in order to educe the
eccentricity measured.

CAUTION! The current eccentricity of 1.0 mm gives
rise to a force more or less equivalent to that genera-
ted by an imbalance of 33.2 gr at a speed of 120
km/hour.

CAUTION

Eccentricity display