beautypg.com

CEMB USA C75 (A) User Manual

Page 28

background image

I 0202 - 28

GB

7.4.2 - WHEEL BALANCER CALIBRATION

For calibration of the machine, proceed as follows:
- Use a medium-sized metal wheel. Example: 6" x 14" (± 1")
- Preset the wheel dimensions with GREAT CARE.
- Follow the instructions appearing on the monitor.

7.4.3 - AMBIENT TEMPERATURE

Ambient temperature is important for correct use of the sonars. Set the average temperature of the area
where the wheel balancer is installed.

7.4.4 - SELF-DIAGNOSTICS

An automatic self-diagnostics cycle is provided for easier trouble shooting. At the end of the self-
diagnostics cycle, several parameters are displayed which are useful for the Technical Service Depart-
ment in order to identify machine faults.

: returns to previous menu.

7.4.4.1 - TO CHECK THE ENCODER
When the spindle is rotated:
- the angular position “POS” should vary from 0 to 128;
- the wording “UP” should appear when rotated clockwise and “DOWN” when rotated in the opposite
direction.

tyre

Encoder check

Check for correct opera-
tion of the distance gauge;
the number increases
when the gauge is pulled
out.

Check for correct ope-
ration of the diameter
gauge; the number
increases when the
gauge is rotated
outwards

Check of the width
sonar: the number
decreases when a
surface is approached
to the sonar

Check of the eccentricity sonar (option):
the number decreases when a surface
is approached to the sonar

In the event of failure or faulty operation of the wheel balancing machine, notify the Technical Service
of all the parameters displayed.