beautypg.com

5 control of serial output rs232c (option) – CEMB USA C75 (A) User Manual

Page 29

background image

I 0202 - 29

GB

7.5 CONTROL OF SERIAL OUTPUT RS232C (OPTION)

This option enables/disables the sending of the measured unbalance and phase values to serial output
RS232C.
Transmission speed

= 9600 baud

Data format

= 7 bit Start

7 bit Data

1

bit

Even

parity

1 bit Stop

At the end of each unbalancing measuring spin, the balancing machine enables the RTS signal, then places
the "$" character on standby to be able to transmit the data; all functions remain on hold until data transmission
is enabled, at the end of which the RTS signal is reset to the inactive state.
The items of data transmitted via serial line are in ASCII format and are separated between each
other by the character (0x0d).

Sending sequence is as follows:

- 00000

- Value of correction weight, left side

- Correction phase, left side

- Value of correction weight, right side

- Correction phase, right side

The fi rst 5 zero bytes represents the start of transmission message. The correction values are expressed
in grams, in steps of .1 gram.
The phase values are expressed in degrees, in the range 0% 359
See specifi c computer board on exploded drawings.