MoTeC ADL2 EDL2 User Manual
Page 31
MoTeC
Installation
29
ADL2 Setup
Setup for the ADL2 is done in the ‘Inputs | Communications’ setup screen.
Select a communications template that matches the ECU type and ECU
telemetry set.
In the displayed channel list, check those channels that you wish to receive in
the ADL2
Interruption of the Data
Note that the data flow to the ADL2 will be interrupted while a computer is
connected to the ECU and will not resume for up to 10 seconds after the
computer has been unplugged. During this period any value that comes from
the ECU, such as RPM or Engine Temperature will not be updated and will
normally be displayed as zero. On latter versions of the ECU software the 10
second delay is reduced to 1 second.
Connection via CAN
The ADL2 and ECU must be connected on the same CAN bus.
See Appendix H: CAN Wiring for wiring details.
ECU Setup
Set the ‘CAN Data Set’ to a set supported by the ADL2 (normally set 1).
The ‘CAN Address’ must also be set. Normal value for ADL2 is 1520. This is
a decimal value that corresponds to a hexadecimal value of 0x5F0 in the
ADL2.
ADL2 Setup
Setup for the ADL2 is done in the ‘Inputs | Communications’ setup screen.
Select a communications template that matches the ECU type and ECU set.
In the displayed channel list, check those channels that you wish to receive in
the ADL2.
ECU Sensor Calibrations
Metric Calibration of the sensors should be used in the ECU otherwise special
scaling is required in the ADL2 communications setup.