beautypg.com

MoTeC ADL2 EDL2 User Manual

Page 18

background image

16 Overview

• Absolute Voltage: The sensor voltage is independent of the sensor supply

voltage

• Ratiometric Voltage: The sensor voltage is proportional to the 5V sensor

supply voltage

• Variable Resistance: The sensor resistance can be entered directly.
• On/Off : The voltage for on and off can be defined

Input Voltage Range

The measurable input voltage range is 0 to 5.5V on inputs AV1 to 4 and AV11
to 14 and is 0 to 15 Volts on all other AV inputs.

Specifications

For full specifications see Appendix D: Input Characteristics.

Analog Temp Inputs

The 8 Analog Temp inputs are identical to the Analog Voltage inputs, except
that they contain a 1000 ohm resistor which is connected internally from the
input pin to the 5V sensor supply. This allows the Analog Temp inputs to be
used with two wire variable resistance sensors such as:

• Two wire thermistor temperature sensors
• Two wire variable resistance pressure sensors

Some voltage output sensors can also be used if they can drive the 1000 ohm
resistor without causing an error in their reading (eg MoTeC Thermocouple
Amplifier). Additionally, on/off switch signals may be connected.

Options

Note that the number of inputs that are available depends on which options
are enabled. See Appendix B: Options Summary for details.

Measurement Methods

These inputs use the same measurement methods as the Analog Voltage
Inputs.

Input Voltage Range

The measurable input voltage range is 0 to 15 Volts. This allows selection
from a wide range of sensors.