beautypg.com

B&K Precision 9130 - Manual User Manual

Page 29

background image

29

APPly:CURRent[:LEVel][:IMMediate][:AMPLitude]?

This command is used to read out the 3 channels’ current setting value at the same time.

Parameter type: none

Returned value: The 3 channels’ current setting value.

Example: APP:CURR?

APPly:PROTvoltage[:LEVel][:IMMediate][:AMPLitude]

This command is used to set the max voltage of the 3 channels at the same time.

Parameter type: 3 channels’ max voltage setting value.

You can set the 1

st

,2

nd

, and 3

rd

channels in one string.

Returned value: none

Example: APP:PROT 1,2,3 (set CH1, CH2, CH3 max. voltages as 1V,2V,3V respectively)

APPly:PROTvoltage[:LEVel][:IMMediate][:AMPLitude]?

This command is used to read out the 3 channels’ max voltage at the same time.

Parameter type: none

Returned value: The 3 channels’ max voltage value.

Example: APP:PROT?

APPly:OUT[:STATe]

This command is used to control the 3 channels’ ON/OFF status at the same time.

Parameter type: 0|1|ON|OFF

Returned value: none

Example: APP:OUT ON, OFF, ON

APP:OUT 1,0,1 (Set CH1, CH2, CH3 output to ON, OFF, ON respectively)

APPly:OUT[:STATe]?

This command is used to read out the 3 channels ON/OFF status at the same time.

Parameter type: none

Returned value: 0|1|ON|OFF

Example: APP:OUT?

MEASure[:SCALar]:VOLTage:ALL[:DC]?

This command is used to read out the measured output voltage value of the 3 channels simultaneously.

Parameter type: none

Returned value: 3 channels’ actual measured output voltage

Example: MEAS:VOLT:ALL?

MEASure[:SCALar]:CURRent:ALL[:DC]?

This command is used to read out the measured output current value of the 3 channels simultaneously.

Parameter type: none

Returned value: 3 channels’ actual measured output current

Example: MEAS:CURR:ALL?