17

Power SN

display the serial number

Soft Version

Display the firmware version

Cal Information

Error Information

Exit

Exit Menu

4.5 Panel Operation

Channel Operation

When the power supply is in “METER” mode, you can select a channel using the arrow keys

.

OUT ON/OFF

Pressing

On/Off

toggles the output state of all 3 channels of the power supply. If the output state is ON,

press it, to turn the output state to OFF. While the output state is OFF, press

On/Off

and the power supply

output will turn ON.

To control channels individually, press one of the number keys

1

,

2

3

corresponding to each channel.

Key

1

controls the output state of the first channel, key

2

controls the output state of the second channel

and key

3

controls the output state of the third channel.

When the power supply is in remote mode, you can set the output state by sending SCPI command( OUTPut:

ON | OFF

~ The Output state operation doesn’t affect any other parameter.

Note: The

On/Off

key controls the output state of all 3 channels simultaneously.

If you want to control the output state of individual channels, use the number keys 1-3.

Timer Operation

If you have set the output timer and the power supply is in “METER” mode, you can check the remaining time

by pressing

0

. When the timer expires, the power supply will turn off the channel automatically.

Set Voltage

Solution 1: Press

V-set

V-set

, enter a numeric value (via key pad) then press

Enter