beautypg.com

Iso 16750-2 parameters, 12v off – B&K Precision 9116 - Manual User Manual

Page 57

background image

44

4.

While 12V or 24V is flashing, use keys to toggle between the two options. Set to

12V for the 12V test function and 24V for the 24V test function.

5.

Use the key to select Off/On and use keys to toggle between the two options.

Choose On to be able to run the function.

6.

Once both parameters are set, press

to confirm the changed settings and press

twice to exit the menu. If the DIN40839 function was setup properly, the Trig

indicator will be highlighted and DIN40839 will be shown on the front panel, shown

below.

7.

To enable the DIN40839 function, press the

key, on the front panel. The proper

voltage (12V or 24V) should be metered on the front panel display.

8.

To run the DIN40839 function press shift and enter to trigger the test to run.

9.

Repeat step 8 to trigger the function to run as many times as needed.

ISO 16750-2 Parameters

The ISO16750-2 function contains three different test simulations, Short voltage drop, Profile

for the reset test, and Starting profile. All three test simulations are based on the ISO 16750-2

requirements and applies to electric and electronic systems/components for vehicles. The pulse

shapes and parameters are shown below:

0.000V 0.000A

0.0W

DIN40839

Trig

DIN40839

12V Off

This manual is related to the following products: