Fluke Networks OptiView™ Integrated Network Analyzer
1 Legnth accuracy is dependent on the actual cable under test matching the cable type selected on the Cable Test/Twisted-Pair detail screen and its
NVP (nominal velocity of propagation) matching that of the ideal cable of the selected type.
2 Battery will not charge below 12
° C (53.0°F)
Media Continued
Receive Level
100 to 5000mVp-p, +/- 5% Resolution: 1 Ohm
Datalink Signal
500mVp-p to 4000mVp-p Resolution: 10mV
Measuring Terminated Cables
Able to analyze individual twisted-pairs of a cable that are terminated into most equipment vendors’ Ethernet
ports such as on a hub, switch or NIC. All cable tests other than wiremap and office locator ID are operational in
the presence of datalink signal.
GBIC Identification
Identifies and operates with the following GBIC module types per SFF Document Number SFF-8053, Gigabit
Interface Converter, Rev. 5.4: LX (1300nm), SX (850nm)
Wiremapper/Office Locator Compatibility
Detects combinations of shorts, opens, and connector miswires. Compatible with wire mapper/office locators
(also called wire map adapter) labeled for Fluke Networks OptiView analyzer
Open, short or with wire map adapter
1 to 305m (3ft to 1000ft) +/- [2% of reading + 0.3m (1ft)]
Terminated with >=15% reflection
1 to 153m (3ft to 500ft) +/- [5% of reading + 0.3m (1ft)]
Environmental and Safety
Operating Temperature
2
10
°C to 30°C (50°F to 86°F) with up to 95% Relative Humidity
10
°C to 40°C (50°F to 104°F) with up to 75% Relative Humidity
Non-Operating Temperature
-20
°C to +60°C (-4°F to +140°F)
Approvals
AC adapter/charger has UL, CSA, and CE approvals or other approvals valid in the USA, Canada, and Europe
Electromagnetic Interference
Complies to EN61326, CLASS B Requirements. Exempt for USA and Canadian emissions regulations if it does not
interfere with licensed communications
Shock and vibration
Meets requirements of MIL-PRF-28800F for Class 3 equipment
Laser
Class 1 Laser Product, complies with 21 CFR 1040.10 and 1040.11, CFR(J)
Safety
(CSA) Complies to CSA C22.2 No. 950 Canadian standards), and UL 1950 (US standards) (CE) Complies with
European Union directives EN60950 3rd edition and EN61326
EMC
Satisfies requirements of EN61326