Measurement capabilities
Source control
Number of measurement channels
Up to 4 independent measurement channels. A measurement channel is coupled
to stimulus response settings including frequency, IF bandwidth, power level,
and number of points.
Number of display windows
Each measurement channel has a display window. Up to 4 display windows (channels)
can be displayed.
Number of traces
4 data traces and 4 memory traces per channel
Measurement choices
Option E5061A/E5062A-150/175: S
11
, S
21
Option E5061A/E5062A-250/275: S
11
, S
21
, S
12
, S
22
Measurement parameter conversion
Available to convert S-parameters into reflection impedance, transmission impedance,
reflection admittance, transmission admittance, and 1/S.
Data formats
Log magnitude, linear magnitude, phase, expanded phase, positive phase,
group delay, SWR, real, imaginary, Smith chart, polar.
Data markers
10 independent markers per trace. Reference marker available
for delta marker operation. Smith chart format includes 5 marker formats:
linear magnitude/phase, log magnitude/phase, real/imaginary,
R + jX, and G + jB. Polar chart format includes 3 marker formats:
linear magnitude/phase, log magnitude/phase, and real/imaginary.
Marker functions
Marker search
Max value, min value, multi-peak, multi-target, peak, peak left, peak right, target,
target left, target right, and width parameters with user-defined bandwidth values.
Marker-to functions
Set start, stop, center to active marker stimulus value; set reference to active
marker response value; set electrical delay to group delay at active marker.
Search range
User definable.
Tracking
Performs marker search continuously or on demand.
Fault location functions (Option E5061A/E5062A-100)
Transformation to distance and time domain
Selectable transformation type from bandpass, lowpass impulse, lowpass step.
Selectable window from maximum, normal and minimum.
Measured number of points per sweep
User definable from 2 to 1601.
Sweep type
Linear sweep, segment sweep, log sweep and power sweep.
Segment sweep
Define independent sweep segments. Set number of points, test port power levels,
IF bandwidth, delay time, sweep time and sweep mode independently for each segment.
Sweep trigger
Set to continuous, hold, or single, sweep with internal, external, manual,
or bus trigger.
Power
Set source power from -5 dBm (-45 dBm for option E5061A/E5062A-1E1/250/275)
to 10 dBm. The power slope function compensates source power level error.