High accuracy power meter (option 0019) – Atec Anritsu-MT8212E-MT8213E User Manual
Page 8

PN: 11410-00485 Rev. M
MT8212E and MT8213E TDS
Specifications
Cell Master™ MT8212E and MT8213E
Power Meter
Frequency
Center/Start/Stop, Span, Frequency Step, Signal Standard, Channel #, Full Band
Amplitude
Maximum, Minimum, Offset, Relative On/Off, Units, Auto Scale
Average
Acquisition Fast/Med/Slow, # of Running Averages
Limits
Limit On/Off, Limit Upper/Lower
Frequency Range
10 MHz to 4 GHz (MT8212E), 10 MHz to 6 GHz (MT8213E)
Span
1 kHz to 100 MHz
Display Range
–140 dBm to +30 dBm, ≤ 40 dB span
Measurement Range
–120 dBm to +26 dBm
Offset Range
0 dB to +100 dB (External Gain or Loss)
VSWR
2:1 typical
Maximum Continuous Input Power
+30 dBm
Accuracy
Same as Spectrum Analyzer
Application Options
Impedance (50 Ω, 75 Ω, Other)
High Accuracy Power Meter (Option 0019)
(Requires external USB Power Sensor(s))
Amplitude
Maximum, Minimum, Offset, Relative On/Off, Units, Auto Scale
Average
# of Running Averages, Max Hold
Zero/Cal
Zero On/Off, Cal Factor (Center Frequency, Signal Standard)
Limits
Limit On/Off, Limit Upper/Lower
Notes:
1. Total RSS measurement uncertainty (0 ºC to 50 ºC) for power measurements of a CW signal greater than –20 dBm with zero mismatch errors.
2. Expanded uncertainty with K = 2 for power measurements of a CW signal greater than +20 dBm with a matched load. Measurement results
referenced to the input side of the sensor.
3. Expanded uncertainty with K = 2 for power measurements of a CW signal greater than –20 dBm with zero mismatch errors.
Power Sensor Model
PSN50
MA24104A/05A
MA24106A
MA24108A/18A/26A
Description
High Accuracy
RF Power Sensor
Inline Bi-Directional
High Power Sensor
High Accuracy
RF Power Sensor
Microwave USB
Power Sensor
Frequency Range
50 MHz to 6 GHz
600 MHz to 4 GHz
(MA24104A)
350 MHz to 4 GHz
(MA24105A)
50 MHz to 6 GHz
10 MHz to 8 GHz
(MA24108A)
10 MHz to 18 GHz
(MA24118A)
10 MHz to 26 GHz
(MA24126A)
Connector
Type N(m), 50 Ω
Type N(m), 50 Ω
(MA24104A)
Type N(f), 50 Ω
(MA24105A)
Type N(m), 50 Ω
Type N(m), 50 Ω
(MA24108A/18A)
Type K(m), 50 Ω
(MA24126A)
Dynamic Range
–30 dBm to +20 dBm
(0.001 mW to 100 mW)
+3 dBm to +51.76 dBm
(2 mW to 150 W)
–40 dBm to +23 dBm
(0.1 µW to 200 mW)
–40 dBm to +20 dBm
(0.1 µW to 100 mW)
VBW
100 Hz
100 Hz
100 Hz
50 kHz
Measurand
True-RMS
True-RMS
True-RMS
True-RMS, Slot Power,
Burst Average Power
Measurement Uncertainty
± 0.16 dB
1
± 0.17 dB
2
± 0.16 dB
1
± 0.18 dB
3
Datasheet
(for complete specifications)
11410-00414
11410-00483
(MA24104A)
11410-00621
(MA24105A)
11410-00424
11410-00504