MT8212E and MT8213E TDS

Specifications

Cell Master™ MT8212E and MT8213E

Cable and Antenna Analyzer

Measurements

Measurements

VSWR
Return Loss
Cable Loss
Distance-to-Fault (DTF) Return Loss
Distance-to-Fault (DTF) VSWR
1-Port Phase
Smith Chart (50/75 Ω selectable)

Setup Parameters

Measurement Display

Single/Dual Measurement Display with independent markers

Frequency

Start/Stop, Signal Standard, Start Cal

DTF

Start/Stop, DTF Aid, Units (m/ft), Cable Loss, Propagation Velocity, Cable, Windowing

Windowing

Rectangular, Normal Side Lobe, Low Side Lobe, Minimum Side Lobe

Amplitude

Top, Bottom Auto Scale, Full Scale

Sweep

Run/Hold, Single/Continuous, RF Immunity (High/Low), Data Points, Averaging/Smoothing,

Output Power (High/Low), RF Pwr When Hold (On/Off)

Data Points

137, 275, 551, 1102, 2204

Markers

Markers 1-6 (On/Off), Delta Makers 1-6 (On/Off), Marker to Peak/Valley, Peak/Valley Auto,

Marker Table (On/Off), All Markers Off

Traces

Recall, Copy to Display Memory, No Trace Math, Trace ± Memory, Trace Overlay (On/Off)

Limit Line

On/Off, Single Limit, Multi-segment Edit, Limit Alarm (On/Off), Pass Fail Message (On/Off), Pass/Fail

(Unbounded/Bounded), Warning Limit Offset, Clear Limit

Calibration

Start Cal, Cal Type (Standard/FlexCal), Disp Valid Cal Temp Range

Save/Recall

Setups, Measurements, Screen Shots (.jpg) (save only)

Frequency

Frequency Range

2 MHz to 4 GHz (MT8212E), 2 MHz to 6 GHz (MT8213E)

Frequency Accuracy

≤ ± 2.5 ppm @ 25 ºC

Frequency Resolution

1 kHz (RF immunity low), 100 kHz (RF immunity high)

Output Power

High

0 dBm, typical

Low

–30 dBm, typical

Interference Immunity

On-Channel

+17 dBm @ > 1.0 MHz from carrier frequency

On-Frequency

0 dBm within ± 10 kHz of the carrier frequency

Measurement Speed

Return Loss

≤ 1.00 ms/data point, RF immunity low, typical

Distance-to-Fault

≤ 1.25 ms/data point, RF immunity low, typical

Return Loss

Measurement Range

0 dB to 60 dB

Resolution

0.01 dB

VSWR

Measurement Range

1:1 to 65:1

Resolution

0.01

Cable Loss

Measurement Range

0 dB to 30 dB

Resolution

0.01 dB

Distance-to-Fault

Vertical Range Return Loss

0 dB to 60 dB

Vertical Range VSWR

1:1 to 65:1

Fault Resolution (meters)

(1.5 x 10

8

x vp) / ΔF (vp = velocity propagation constant, ΔF is F2–F1 in Hz)

Horizontal Range (meters)

0 to (Data Points–1) x Fault Resolution, to a maximum of 1500 meters (4921 feet)

1-Port Phase

Measurement Range

–180º to +180º

Resolution

0.01º

Smith Chart

Resolution

0.01 50/75 Ohm Selectable