beautypg.com

Channel scanner (option 0027), Cw signal generator (option 0028), Gated sweep (option 0090) – Atec Anritsu-MT8212E-MT8213E User Manual

Page 7

background image

Cell Master™ MT8212E and MT8213E

Specifications

MT8212E and MT8213E TDS

PN: 11410-00485 Rev. M

7 of

32

Channel Scanner (Option 0027)

Number of Channels

1 to 20 Channels

Measurements

Graph/Table, Max Hold (On/5 s/Off), Freq/Channel, Current/Max, Single/Dual Color

Scanner

Scan Channels, Scan Frequencies, Scan Customer List, Scan Script Master™

Amplitude

Reference Level, Scale

Custom Scan

Signal Standard, Channel, # of Channels, Channel Step Size, Custom Scan

Frequency Range

100 kHz to 4 GHz (MT8212E), 100 kHz to 6 GHz (MT8213E)

Frequency Accuracy

± 10 Hz + Time base error

Measurement Range

–110 dBm to +26 dBm

Application Options

Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)

CW Signal Generator (Option 0028)

(Requires CW Signal Generator Kit, P/N 69793)

Setup Parameters

Frequency

Frequency, Signal Standard, Channel Number, Display Setup Help

Amplitude

Power Level (Low/High), Offset (dB)

Frequency Range

2 MHz to 2 GHz

Frequency Reference

Accuracy: ± 1.5 ppm (25 °C ± 25 °C) + aging, < ± 50 ppb with GPS On

Output Power

High 0 dBm typical, Low –30 dBm typical
Attenuator (included in kit 69793): 0 to 90 dB in 1 dB steps

Gated Sweep (Option 0090)

Mode

Spectrum Analyzer, Sweep

Trigger

External TTL

Setup

Gated Sweep (On/Off)
Gate Polarity (Rising, Falling)
Gate Delay (0 ms to 65 ms typical)
Gate Length (1 μs to 65 ms typical)
Zero Span Time