ATAS ScanRoof User Manual
Installation guide, Top view, Open framing solid substrate
SCANROOF panels are always installed from lower right
of any roof section to upper left. Each fully applied
panel affords 18.1 square feet of coverage and each
square (100 square feet - 5.52 panels) of SCANROOF
weighs approximately 145 pounds.
Minimum roof slope - 3:12.
21 Modules - 13’-10” (nom.) overall length
Lap Area
Lap Area
20 Modules - 13’-2” (nom.) Coverage
7-7/8”
21”
16-1/2” r
ef
.
Top View
FASTENER REQUIREMENTS
SWR8XX - “Stitch Screws” 10 per panel
SWR9XX - 10 for each panel installed at eave
RSS014 or SWR970 - Anchor Screws 8 per panel
(Use RSS014 for attachment to metal and SWR970 for attachment to wood.)
For basic wind speeds of 100 mph - Panels can obtain 140 mph winds
Consult ATAS for more information.
Appropriate
Anchor Screw
Scan Roof Panel
SWR8XX Stitch Screws
Intergral “Z” Purlin
Scan Roof Panel
Substrate
Line
HORIZONTAL LAP
1-1/2” Hat
Channel
2” X 4”
Wood Stud
Open Framing
Solid Substrate
4’ Max
Appropriate
Anchor Screw
SWR8XX Stitch Screws
Intergral “Z” Purlin
Panel Overlap
21” Nom.
16-1/2” (nom.) coverage
2” Nom.
1”
Side View
Installation Guide
Review and understand complete
guide before beginning installation.
This guide has been prepared as
suggested details for particular design
conditions. Each condition has certain
limitations to performance, aesthetics or
economics. Professionals qualified to assess
this information for a specific projects should
determine that the selection and installation are made
to their requirements. ATAS cannot assume any
responsibility for the actual selection and/or installation
of materials. The panels, flashing and trim shown in this
guide are illustrated over solid and square substrate. It
is assumed that the structure has been designed and
prepared in accordance with local building codes,
including appropriate underlayment.