ATAS Design Wall Panel User Manual
Atas international, inc, Specification data sheet, Design wall
ATAS INTERNATIONAL, INC.
SPECIFICATION DATA SHEET
1. PRODUCT NAME
DESIGN WALL™
2. MANUFACTURER
ATAS INTERNATIONAL, INC.
Website: www.atas.com
Email: [email protected]
Corporate Headquarters:
Allentown, PA 18106
Phone: (610) 395-8445
Fax: (610) 395-9342
Western Facility:
Mesa, AZ 85204
Phone: (480) 558-7210
Fax: (480) 558-7217
Southern Facility:
Maryville, TN 37801
Phone: (800) 468-1441
3. PRODUCT DESCRIPTION
Basic Uses:
Design Wall consists of a 12” wide panel in
two distinct profiles. Panels may be used for
wall applications, soffits, fascia or equipment
screens.
Composition & Materials:
Standard Offerings: Design Wall panels are roll-
formed from .032, .040 and .050 Aluminum;
24 gauge Metallic Coated Steel; and 24 gauge
55% Al-Zn alloy Coated Steel with acrylic
coating.
Special Offerings: 20 and 22 gauge Metallic
Coated Steel and 22 gauge 55% Al-Zn alloy
Coated Steel with acrylic coating. Subject to
minimum quantities and lead time.
Sizes:
Design Wall is a 12” wide panel in two distinct
profiles. DSF and DSH panels are 1 3/4” high;
DWF and DWH panels are 1 1/8” high. The
“F” code indicates a flat or flush panel and
the “H” code indicates a “board” panel. The
“board” panels have an upside of 6” that
may be extended in 1” increments (subject
to minimum orders). For every 1” change
on the “board”, the lower part of the panel
is decreased to give net 12” coverage (with
a maximum ”board width of 11”). All panels
have the same lock configuration and
stiffening ribs standard, specify without. The
DS panel is used primarily where increased
structural integrity of the panel is required.
Panels of .032 aluminum can be lanced for
ventilation. Panel lengths are cut to customer
specifications with a minimum of 3’-0”,
maximum to transportation limitations and/or
product and project design considerations.
Colors & Finishes:
A choice of 30 stock colors is available in a
KYNAR 500® PVDF or HYLAR 5000® PVDF finish.
(Request color chart or chips). An anodized
finish is available in Clear or Dark Bronze.
Texture may be smooth or embossed.
4. TECHNICAL DATA
KYNAR 500® PVDF or HYLAR 5000® PVDF based
finishes tested by paint supplier for:
Dry Film Thickness: ASTM D 1005, ASTM D
1400, ASTM D 4138 or ASTM D 5796
Specular Gloss: ASTM D 523
Pencil Hardness: ASTM D 3363
T-Bend Flexibility: ASTM D 4145
Mandrel Bend Flexibility: ASTM D 522
Impact Resistance: ASTM D 2794
Adhesion: ASTM D 3359
Water Immersion Resistance: ASTM D 870
Abrasion Resistance: ASTM D 968
Acid Resistance: ASTM D 1308
Acid Rain Resistance (Kesternich):
ASTM G 87 or DIN 50018
Salt Spray: ASTM B 117
Cyclic Salt Spray: ASTM D 5894
and ASTM D 5487
Humidity Resistance: ASTM D 2247
Accelerated Weathering: ASTM D 822 and
ASTM G 155, ASTM G 151 or ASTM G 153
Color Retention, Florida Exposure:
ASTM D 2244
Chalking Resistance: ASTM D 4214
Cleveland Condensing Cabinet: ASTM D 4585
Cure Test, MEK Resistance: ASTM D 5402
Alkali Resistance, Sodium Hydroxide:
ASTM D 1308, Procedure 7.2
Flame Spread Rating: ASTM E 84
Organic coatings meet requirements of AAMA
2605 when applied to aluminum.
Panel testing/ratings:
Galvanized Steel: ASTM A 653
55% Al-Zn alloy Coated Steel: ASTM A 792
Aluminum: ASTM B 209
Copper: ASTM B 370
Coil Coating: ASTM A 755
Field Tested and Approved.
Load Tables available upon request.
5. INSTALLATION
Design Wall may be installed horizontally
or vertically. Installation manuals and
hands-on training via seminars are available
through ATAS. Visit www.atas.com for more
information.
6. AVAILABILITY & COST
Availability:
Design Wall panels are available through
ATAS product distributors. A complete line
of related components and trim accessories
is available to complete the wall system. In
addition, a complete line of rainware and
perimeter roof edge trims can be supplied
by ATAS to complement the wall system. Flat
sheet and/or coil stock is available in matching
color for fabrication of related components by
the installing contractor.
Cost:
Contact ATAS product distributors for current
pricing.
7. WARRANTY
Products coated with a fluoropolymer, KYNAR
500® PVDF or HYLAR 5000® PVDF finish carry a
limited warranty against chalking and fading.
8. MAINTENANCE
Design Wall panels are virtually maintenance
free. Surface residue may be easily removed by
conventional cleaning methods. For painted
products, minor scratches should be touched
up with a matching paint, available from ATAS
International, Inc.
9. TECHNICAL SERVICES
Complete technical information and literature
are available at www.atas.com. ATAS will assist
with design ideas and shop drawings.
10. FILING SYSTEM
• www.atas.com
• Additional product information is available
from the manufacturer upon request.
Design Wall
TM
is a trademark of ATAS International, Inc.
KYNAR 500
®
is a registered trademark of Arkema.
HYLAR 5000
®
is a registered trademark of Solvay Solexis, Inc.
© ATAS International, Inc.
LRD0213 LAT845
DWF
12"
4"
11⁄8"
12"
4"
1¾"
DSF
12"
6"
11 10 9 8 7
1¾"
DSH
11⁄8"
12"
6"
11 10 9 8 7
DWH
DWF
12"
4"
11⁄8"
12"
4"
1¾"
DSF
12"
6"
11 10 9 8 7
1¾"
DSH
11⁄8"
12"
6"
11 10 9 8 7
DWH