Associated Equipment 12-1012 Manual User Manual
Page 15

_______________________________________________________________________________
-
15 -
Model 12-1012 Users’ Manual Version 13.08
Associated Equipment Corp.
5043 Farlin Ave.
800-949-1472(US)
St. Louis, MO 63115 314-385-5178 (Outside US)
RESULTS:
Good
12.40V 419 CCA
Int.R: 6.43mΩ
LIFE: 76%
Here, it will let you select your choice from the Menu:
New: Clear Memory
Selecting this item will allow the tester to clear the last tested results
stored in its memory and begin a new test.
Continue… Test
Selecting this item will allow you to continue the last test on the same
car from where you had stopped.
For example:
If you had done Battery Test and later you wish to do Alternator Test
or Grounding Test on the same car, just select this item and it will
update the results after each test in its memory so that it can be review
later or to be printed out from the printer.
Last Test Results
Here it will let you review the test results of the last tested car. The
results stored will always depends on the tests that you had done.
Use or keys to scroll for the pages during viewing.
Examples:
3. After you have made your choice, selecting “New: Clear Memory” or
“Continue…Test” will proceed to the display below: (Fig. 14)
Figure 13
Figure 14
Figure 12
Battery Test
Grounding Test
Starter Test
Alternator Test
ENGINE GROUND
Results: OK
Resistance is