ABUS FU8007 Secvest 2WAY Base Kit Operating instructions User Manual
Page 41

41
19.1. Errors, meanings, causes and suggested solutions
Displayed error
Meaning
Possible causes
Suggested solutions
AC Fail
The 230 V AC system
power supply is missing.
• The main fuse of the PSU on the wireless
alarm system is not fitted correctly or is
defective.
• The connecting cable between the system
and the base plate is not inserted correctly.
• The main power supply to the PSU of the
base plate has failed or the power cable
was not fitted correctly.
• PSU in base plate is defective.
• Replace the main fuse with one of the same
rating.
• Check that the fuse is correctly fitted.
• Check the correct installation of the system to
the base plate and plug the connecting cable
into the correct base plate socket.
• Check that your mains power fuse is active for
the system. Is there a 230 V power supply?
• Check the correct connection between the mains
power line and the PSU clamp.
• Contact
your
installer.
WAM__PSU Fail
230 V AC power supply is
missing in the accessory
module.
• The mains power cable to the 12 V power
supply is not connected correctly.
• The PSU is not supplied with power.
• The PSU that supplies power to the
accessory module is defective.
• Check the correct installation of the 12 V DC
connecting cable.
• Check that the PSU is inserted and the red LED
on the PSU is lit.
• Contact
your
installer.
Batt Low
No battery power supply
to the system.
• The inserted batteries are not fully charged.
• This error should disappear when the batteries
are fully charged.
• After a maximum of 4 hours, the batteries are
charged and this display disappears.
WAM Low Batt
No battery power supply
to the accessory module.
• The lead-acid battery has not yet been
charged.
• No lead-acid battery was connected.
• This error should disappear when the battery is
fully charged.
• Check the correct installation of the 6 V, 1.2 Ah
lead-acid battery in the accessory module.