12. Switching example using Terxon MX


The purpose of this sample installation is to explain the basic use of the Terxon 2WAY wireless module.
First, start with the wiring, setting the jumpers and setting the DIP switches. The following graphic shows
the connection and the settings. If you do not use an externally wired alarm device, you have to set the wire
bridge between connections “TR” and “0 V” on the PCB of the alarm centre. Also read the basic notes on
starting up the alarm centre. Now program the alarm centre.

The alarm centre is to operate as a partitioned system.
Menu item: 098 – Factory settings

Exit mode for overall area: Menu item 039 with 3 immediately

You program the zones used here as follows:
Zone 1: Menu item 001 with12 KF Key switch
Zone 2: Menu item 002 with 01 PA Panic

You program the outputs used here as follows:
Output 1: Menu item 81 with 00 Siren
Output 2: Menu item 82 with 08 Flash
Output 3: Menu item 83 with 26 Active 1

In addition: Menu item 170 with 00 Stable and menu item 171 with A


Train your wireless components and program the Terxon 2WAY wireless module according to these
instructions. This switching example can be used to integrate all 5 wireless components into the
alarm system.
Secvest 2WAY wireless outdoor sounder

Flash and siren if alarm is activated

Secvest wireless indoor sounder

Siren if alarm is activated

Wireless remote control 2WAY

Activation and deactivation area A, panic and query of the
status of the alarm centre

Wireless control unit 2WAY

Activation and deactivation area A and query of the status
of the alarm centre

Secvest Key

Activation and deactivation area A


You can operate the alarm centre using the corresponding wireless components and the wired operating
units of the centre itself.