Oscilloscope displays – Extron Electronics MVP 104GX User Guide User Manual
Page 17
MVP 104GX Installation
2-9
Oscilloscope displays
What you see on the oscilloscope while adjusting the MVP 104GX to match the
genlock signal depends on the type of signal used, the type of oscilloscope, and the
procedure the scope requires. This section shows some examples of oscilloscope
displays.
Figure 2-6 below shows the genlock input signal (top) and an out-of-alignment
NTSC composite sync output signal (bottom) displayed on a waveform monitor to
check for alignment. When the phases are aligned, the wave peaks on the bottom
waveform should line up with those in the reference signal above it.
With this method there is no way to know if the signals are 180º out of phase. A
delayed sweep on a time-based scope would allow a more accurate display of the
input and output signal phase relationships.
Figure 2-6 — Superimposed waveforms
A vectorscope is more accurate than a waveform monitor. Figure 2-7 shows an
example of a vectorscope display when the horizontal phase is adjusted to align it
with the burst (genlock) vector. Adjust the horizontal phase by rotating the encoder
knob until the difference between the two vectors is 0º. This example shows black
burst only (with no color). The burst vector is pointing to the left from the center.
Figure 2-7 — Vectorscope screen during horizontal
phase adjustment
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
350