Extron Electronics IPL 250 Reference Manual User Manual
Page 69

4-13
IPL 250 • SIS Programming and Control
Command/r
esponse table for SIS commands (continued)
Command
ASCII (T
elnet)
(host to IPL)
URL Encoded (W
eb)
(host to IPL)
Response
(IPL to host)
Additional description
Query
bootstrap firmwar
e
version
2Q
2Q
X1!
]
or
V
er02*
X1!
]
The bootstrap firmwar
e is not user
-
replaceable, but you may need this
information during tr
oubleshooting.
Example:
2Q
2Q
2.20
]
Query factory firmwar
e version
3Q
3Q
X1!
(kernel version–model description–date time of upload)
]
or
V
er03*
X1!
(kernel version–model description–date time of upload)
]
Fa
ct
or
y-
in
st
al
le
d
fir
m
w
ar
e
is
d
iff
er
en
t f
ro
m
the bootstrap firmware, but it is also not user-
re
pl
ac
ea
bl
e.
T
hi
s
fir
m
w
ar
e
w
as
in
st
al
le
d
at
th
e
fa
ct
or
y;
it
is
th
e
ve
rs
io
n
th
e
contr
oller
reverts to after a mode 1 r
eset (see chpt. 2).
Example:
3Q
3Q
1.14(1.77-IPL
Series -W
ed, 16 Jan 2003 00:00:00 GMT)
]
In this example the factory firmwar
e version
is 1.14 and the IP
Link kernel version is 1.77
for the IPL
250, dated 16 January 2003.
Query updated firmwar
e version
4Q
4Q
X1!
(kernel version–model description–date time of upload)
]
or
V
er04*
X1!
(kernel version–model description–date time of upload)
]
Use this command to find out which version
of the firmwar
e, if any
, was uploaded into
the contr
oller after it left the factory
Example:
4Q
4Q
1.15*(1.78-IPL
Series -Fri, 17 Jul 2009 21:47:29 GMT)
]
In this example the curr
ent firmwar
e version
is 1.15, the IP
Link kernel version is 1.78, for
the IPL
unit, and the last firmwar
e upload
was on July 17, 2009.
N
Responses to commands differ depending on which, if any
, verbose r
esponse mode the IPL
is in.
) under IP setup commands later in this table.
Request the IPL
’s
part number
N
N
60-1026-81
]
or
Pno
60-1026-81
]
Show the IPL
’s part number
.
Request the
model name
1I
1I
IPL
•
250
]
or
Inf01*IPL
250
]
IPL
250.
Request the
model description
2I
2I
Thr
ee Bi-Dir
ectional Serial Ports [RS232], Four Contact Input Ports, Four Relay
Ports, Four IR Ports, IR Learner
]
or
Inf02* Thr
ee Bi-Dir
ectional Serial Ports [RS232], Four Contact Input Ports,
Four Relay Ports, Four IR Ports, IR Learner
]