COMMAND

DESCRIPTION

[LVOLL,aaa,bbb,ccc,ddd,eee,fff,
ggg,hhh,iii,jjj,kkk,lll,mmm,nnn,o
oo,ppp
]

Preload left channel output volume level for all outputs.
Must send a [TAKE] command to execute changes.

Where

o

aaa = -550 to 90 for output 1

o

bbb = -550 to 90 for output 2

o

ccc = -550 to 90 for output 3

o

ddd = -550 to 90 for output 4

o

eee = -550 to 90 for output 5

o

fff = -550 to 90 for output 6

o

ggg = -550 to 90 for output 7

o

hhh = -550 to 90 for output 8

o

etc.

Note: Level is set in .5 dB steps . For example, –
23.5dB is entered as -235

[LVOLL,?]

Queries any previously loaded LVOLL commands.

[LVOLR,aaa,bbb,ccc,ddd,eee,fff,
ggg,hhh,iii,jjj,kkk,lll,mmm,nnn,o
oo,ppp
]

Preload right channel output volume level for all outputs.
Must send a [TAKE] command to execute changes.

Where

o

aaa = -550 to 90 for output 1

o

bbb = -550 to 90 for output 2

o

ccc = -550 to 90 for output 3

o

ddd = -550 to 90 for output 4

o

eee = -550 to 90 for output 5

o

fff = -550 to 90 for output 6

o

ggg = -550 to 90 for output 7

o

hhh = -550 to 90 for output 8

o

etc.

Note: 90 equals max (+9.0 db), 000 equals factory
default (0 db), -550 equals minimum (-55db)

[LVOLR,?]

Queries any previously loaded LVOLR commands.

Auxiliary Commands


The MSX1616 contains two auxiliary communications ports, port 2 and port 3 (see Setup
Commands
to properly configure ports). You can use both ports to control other devices or
equipment that accept RS232/RS-422/RS-485 command strings. The switcher can store
command strings to an input, an output and/or presets (see Preset Commands). It can force
these commands out or send them when it executes an input, output, or preset.

COMMAND

DESCRIPTION

[PCPpx]

Enable/disable projector port.

Where

o

p = 2 for port 2, 3 for port 3

o

x = 0 to disable, 1 to enable, ? to query

This manual is related to the following products: