Extron Electronics MSX1616HR User Manual
Page 35
33
2002 - INLINE, INC.
MSX1616 OPERATION MANUAL - v1.0 5/8/02
COMMAND
DESCRIPTION
[LVOLL,aaa,bbb,ccc,ddd,eee,fff,
ggg,hhh,iii,jjj,kkk,lll,mmm,nnn,o
oo,ppp]
Preload left channel output volume level for all outputs.
Must send a [TAKE] command to execute changes.
•
Where
o
aaa = -550 to 90 for output 1
o
bbb = -550 to 90 for output 2
o
ccc = -550 to 90 for output 3
o
ddd = -550 to 90 for output 4
o
eee = -550 to 90 for output 5
o
fff = -550 to 90 for output 6
o
ggg = -550 to 90 for output 7
o
hhh = -550 to 90 for output 8
o
etc.
Note: Level is set in .5 dB steps . For example, –
23.5dB is entered as -235
[LVOLL,?]
Queries any previously loaded LVOLL commands.
[LVOLR,aaa,bbb,ccc,ddd,eee,fff,
ggg,hhh,iii,jjj,kkk,lll,mmm,nnn,o
oo,ppp]
Preload right channel output volume level for all outputs.
Must send a [TAKE] command to execute changes.
•
Where
o
aaa = -550 to 90 for output 1
o
bbb = -550 to 90 for output 2
o
ccc = -550 to 90 for output 3
o
ddd = -550 to 90 for output 4
o
eee = -550 to 90 for output 5
o
fff = -550 to 90 for output 6
o
ggg = -550 to 90 for output 7
o
hhh = -550 to 90 for output 8
o
etc.
Note: 90 equals max (+9.0 db), 000 equals factory
default (0 db), -550 equals minimum (-55db)
[LVOLR,?]
Queries any previously loaded LVOLR commands.
Auxiliary Commands
The MSX1616 contains two auxiliary communications ports, port 2 and port 3 (see Setup
Commands to properly configure ports). You can use both ports to control other devices or
equipment that accept RS232/RS-422/RS-485 command strings. The switcher can store
command strings to an input, an output and/or presets (see Preset Commands). It can force
these commands out or send them when it executes an input, output, or preset.
COMMAND
DESCRIPTION
[PCPpx]
Enable/disable projector port.
•
Where
o
p = 2 for port 2, 3 for port 3
o