19
2002 - INLINE, INC.
MSX1616 OPERATION MANUAL - v1.0 5/8/02
Menu Programming
Level Selection
The MSX1616 has six user-definable switching levels:
Level Number: Default Level:
1 RGBHVA
2 RGBHV
3 Audio
4 No
boards
5 No
boards
6 No
boards
Each level can be one of nine board configurations:
•
RGBHVA
•
Red
•
RGBHV
•
Green
•
RGB
•
Blue
•
SYNC
•
No boards
•
Audio
In or Out
Use this function to create a patch using the LCD menu functions:
1. Press
MENU button until
&XUUHQW /HYHO displays in the LCD.
2. Press the soft key pointing to
,Q or 2XW on the LCD.
Result: The LCD shows
,QSXW and 2XWSXW , or the last output or input number
designated.
3. Press the left and right arrow buttons to move forward or backward to the desired input.
4. Use the up and down arrow buttons to move between the
,Q and 2XW fields.
5. Press the left and right arrow buttons to move forward or backward to the desired output
number.
6. Press
ENTER to accept the patch.
Note:
When using the LCD menu, patches are limited to one input and one output.