beautypg.com

Remote operation – Extron Electronics MSX1616HR User Manual

Page 25

background image

23

2002 - INLINE, INC.

MSX1616 OPERATION MANUAL - v1.0 5/8/02

Communication Protocol


The MSX1616 contains three serial ports for communication. You can configure all three ports
to communicate serially via RS-232, RS-422 or RS-485 standards by setting the DIP switches
located at the rear of the unit to the appropriate setting.

Use this port...

To...

1

Directly communicate with the switcher.

2 and 3

Control projectors, Inline products, or other serially
controlled A/V equipment.

Control Port 1

The baud rate is selectable from 1200 to 38,400. You can change the baud rate using the

$GYDQFHG menu option on the LCD on the front panel or via serial control using the [CPxbpsfd]
serial command. Other adjustable parameters for port 1 include flow control (none or Xon/Xoff)
and duplex (full or half). Parity, data bits, and stop bits are predefined and have no affect on port
1. The factory default communication parameters for the control port are:

Communication Parameters

Baud rate

9600

Parity None
Data bits

8

Stop bits

1

Flow control

None

Duplex Full

Protocol Structure


All commands sent to the unit must contain a leading delimiter, the actual command, and an
ending delimiter.

This part of the command string...

Represents:

[

The leading character

BLANK01

The actual command.

]

The ending character

Command Meaning

[ADDR@]

Remove address from unit

[BLANK01]

Blank output #1

[RES1]

Enable serial responses

[MS1O02I01]

Connect input 1 to output 2 at level 1

Remote Operation

This manual is related to the following products: