Set-Up Commands

These commands are for configuring the switcher and only need to be sent once. If using a third
party control system, most commands in this section should be placed in the start-up section of
the program.

COMMAND

DESCRIPTION

[ARC]

Request for model and version information.

[CPx@]

Re-sets a specific port to default of 9600, 8, N and 1.

Where

o

x = 1 - 3 for specific port

[CPx?]

Query a specific port for current settings.

Where

o

x = 1 - 3 for specific port

[CPxbpsfd]

Configures a specific port for baud rate, parity, stop bits, flow control
and duplex.

Where

o

x = 1 - 3 for specific port

o

b = 0 for 1200, 1 for 2400, 2 for 4800, 3 for 9600, 4 for
19200, 5 for 38400

o

p = 0 for no parity, 1 for odd parity, 2 for even parity

o

s = 0 for 1 stop bit, 1 for 2 stop bits

o

f = 0 to disable flow control, 1 to enable flow control

o

d = 0 for full duplex and 1 for half duplex

[DFLTx]

Performs factory reset. The partial reset will default I/O configurations,
volume levels and serial set-up, but does not reset projector codes
and/or presets. A full reset will reset all parameters including projector
codes and presets, and will take up to 2 minutes.

Where

o

x = 0 for partial reset, 1 for full reset

[FPx]

Enable/disable front panel control and request current status.

Where

o

x = 0 to disable, 1 to enable

o

x = ? to request current state

o

x = (left blank) to toggle current state

[LBLIiiabcde…]

Allows for custom labeling to be displayed on LCD for all inputs, up to
20 characters

Where

o

ii = 01 – 16 for input

o

abcde = custom label up to 20 characters, ? to query

[LBLOooabcde…]

Allows for custom labeling to be displayed on LCD for all outputs, up
to 20 characters.

Where

o

oo = 01 - 16 for output

o

abcde = custom label up to 20 characters, ? to query

[RESx]

Enable/disable serial responses from switcher.

Where

o

x = 0 to disable, 1 to enable, ? to query