beautypg.com

Extron Electronics MSX1616HR User Manual

Page 30

background image

28

MSX1616 OPERATION MANUAL - v1.0 5/8/02

2002 - INLINE, INC.

COMMAND

DESCRIPTION

[RGBxx]

RGB delay provides an adjustable delay time between switching sync
and RGB boards.

Where

o

x.x = 0.0 – 6.0 in .1 seconds intervals, ? to query

[VISx]

Enable/Disable Vertical Interval Switching. Requires sources to be
Genlocked. Contact Inline Inc. For specific application support.

Where x = 0 to disable, 1 to enable, ? to query

Level Commands


Level commands are a command subset that involves the assigning of boards into switching
levels. Levels can consist of combinations of R, G, B, HV and audio boards. You can access six
assignable levels via the front panel or serial control. For commands that use level designators,
see Switching Commands and Volume Commands.

Default Levels include:

Level 1 - RGBHVA

Level 2 - RGBHV

Level 3 - Audio

Level 4-6 - No Boards

COMMAND

DEFINITION

[LVLx]

Sets current working level of switcher.

Where

o

x = 1 - 6, x = ? query

[LVL??]

Queries all levels.

[LVLxyyy]

Assigns individual boards to a specific level.

Where

o

x = 1 - 6

o

yyy = RGBHVA for all boards

o

yyy = RGBHV for RGB and sync

o

yyy = RGB for RGB only

o

yyy = SYNC for sync only

o

yyy = AUD for audio only

o

yyy = RONLY for red only

o

yyy = GONLY for green only

o

yyy = BONLY for blue only

o

yyy = NO for no boards

This manual is related to the following products: