Mounting the Unit

The GSS 100 is housed in a rack-mountable, 1U high, half rack-width metal enclosure.

Tabletop Placement

For tabletop or desktop placement only, install the self-adhesive rubber feet (provided) onto
the four corners of the bottom of the enclosure.

Rack Mounting

UL Requirements

The following Underwriters Laboratories (UL) requirements pertain to the installation of the
GSS 100 into a wall or furniture.

1.

Elevated operating ambient temperature — If the unit is installed in a closed or
multi-unit rack assembly, the operating ambient temperature of the rack environment
may be greater than room ambient. Therefore, consider installing the equipment in an
environment compatible with the

113 °F (45 °C)

maximum ambient temperature (Tma)

specified by Extron.

2.

Reduced air flow — Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not compromised.

3.

Mechanical loading — Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.

4.

Circuit overloading — Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits might
have on overcurrent protection and supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.

5.

Reliable earthing (grounding) — Reliable earthing of rack-mounted equipment
should be maintained. Particular attention should be given to supply connections other
than direct connections to the branch circuit (that is, the use of power strips).

Installation instructions

Secure the unit to an optional 1U (one unit high, one unit wide) rack shelf (part number
60-190-01 or 60-604-02) and install the shelf in a rack in accordance with the directions
that accompany the shelf.