Command

ASCII Command

(Host to Unit)

Response

(Unit to Host)

Additional description

Image recall

Recall an image to buffer

EX!

RF

}

Cim

X!]

Select image

X!

to display.

NOTE: It takes several seconds between the issuance of the recall command (

EX!

RF

}

) and the receipt of the Cim response.

Show the image that is
currently displayed

E

RF

}

X!]

The buffer is loaded with image

X!

.

Take

%

Tke

]

Swap the displayed and buffered images using the
selected effect (cut or dissolve).

Switch effect

Set the effect to cut

9*0#

Eff0

]

Set the effect for switching images to cut (immediate).

Set the effect to dissolve

9*1#

Eff1

]

Set the effect for switching images to dissolve.

Read the effect

9#

X@]

Set the dissolve duration

10*

X#

#

Dur

X#]

Set the duration of the dissolve effect to

X#

.

Read the dissolve duration

10#

X#]

The dissolve duration is

X#

.

Source selection

Display pass-through

1!

Chn1

]

Display the pass-through input.

Display last image

0!

Chn0

]

Display the previously selected stored image.

View pass-through status

!

X@]

Pass-through mode is

X@

.

Slide show interval

Set slide show interval

2*

X#

#

Sli

X#]

Set the display time for each image to

X#

seconds.

Read slide show interval

2#

X#]

The display time for each image is

X#

seconds.

Pass-through configuration

Enable pass-through

1*1#

Pas1

]

Include the pass-through input in the slide show.

Disable pass-through

1*0#

Pas0

]

Do not include the pass-through input in the slide show.

Read the pass-through status

1#

X@]

Show the status of the pass-through.

Auto-switch and slide show mode

Set auto-switch and slide
show mode

4*

X$

#

Aut

X$]

Set auto-switch and slide show mode.

X$

definitions:

0 = Off — Auto-switch on loss of pass-through sync

and slide show are disabled.

1 = Off/show — Auto-switch on loss of pass-through

is disabled. Slide show is running.

2 = On/still — On loss of sync on the pass-through

input, auto-switch to display the last-
displayed image until pass-through
sync is restored.

3 = On/show — On loss of sync on the pass-through

input, auto-switch to run the slide
show until sync on the pass-through
input is restored.

Show auto-switch and slide
show mode

4#

X$]

Command and Response Table for SIS Commands

NOTE:

X!

= Image file name

Image name with file extension (*.bmp or *.jpg)

X@

= Cut / dissolve status:

0 = cut

1 = dissolve

Pass-through status:

0 = pass-thu

1 = no pass-thru

X#

= Time (duration)

00 – 50 (0.0 to 5.0 seconds) for dissolve duration

000 – 300 seconds for slide show interval

X$

= Auto-switch / slide show

0 = off

2 = on / still

1 = off / show

3 = on / show

GSS 100 Graphic Still Store • Programming Guide