Name display, Mac address display, Internal temperature display – Extron Electronics GSS 100 User Guide User Manual

Page 21: Baud rate submenu, Ip address submenu, Exit menu

background image

Name display

The read-only Name display shows either the factory default name or a customized name
that can be assigned under RS-232 or Ethernet control. If the name is greater than eight
characters, the display shows the first eight characters of the assigned name and then scrolls
the name to the left to display the remaining characters of the name.
The factory default name is the product name (GSS-100-) plus the last three pairs of
the MAC address (see the “

Programming Guide

“ and “

HTML Control and IPL File

Manager

“ sections to assign a name).

MAC Address display

The read-only MAC Address display shows the hardcoded, factory assigned hardware
address.

Internal Temperature display

The read-only Internal Temperature display shows the Fahrenheit and Celsius measurements
for the GSS temperature.

CAUTION: Temperatures above 150 degrees Fahrenheit (65 degrees Celsius) are

potentially damaging to the GSS.

Baud Rate submenu

The Baud Rate menu is read-only without further action. The menu shows the selected baud
rate for the RS-232 port of the GSS. The default setting is 9600.
To change the baud rate, press and release the Take button. The baud rate display starts
blinking, and can be adjusted by rotating the Adjust/Select knob.

NOTE: The baud rate is also selectable using SIS commands (see the “

Programming

Guide

“ section).

IP address submenu

The read-only IP address menu is read-only without further action. The menu shows the IP
address of the GSS. The factory default IP address is 192.168.254.254.
To change the IP address, one octet at a time, press and release the Take button. The first
(most-significant) octet starts blinking, and can be adjusted by rotating the Adjust/Select
knob. Repeatedly press and release the Take button to cycle through the four IP address
octets, enabling them for editing, one at a time.

NOTE: The IP address is also selectable using SIS commands or the HTML pages (see

the “

Programming Guide

“ and “

HTML Control and IPL File Manager

sections).

Exit menu

Press and release the Next button while in the Exit menu to return the LCD to the default
display cycle.

GSS 100 Graphic Still Store • Operation