Error Responses

When the GSS 100 receives a valid SIS command, it executes the command and sends a
response to the host device. If the unit is unable to execute the command because the
command is invalid or it contains invalid parameters, the unit returns an error response to
the host. The error response codes are:
E10 — Invalid command

E13 — Invalid value (out of range)

E14 — Illegal command for this configuration

E17 — Timeout (caused only by direct write of global presets)

E22 — Busy

E24 — Privilege violation (Ethernet, Extron software only)

E25 — Device not present

E26 — Maximum number of connections exceeded

E27 — Invalid event number

E28 — Bad filename or file not found

Timeout

Pauses of 10 seconds or longer between command ascii characters result in a timeout. The
command operation is aborted with no other indication.

Using the Command and Response Tables

The command and response table begins on the

next page

. Either uppercase or lowercase

letters are acceptable in the command field except where indicated for the audio level (gain
and attenuation) commands. Symbols are used throughout the table to represent variables in
the command/response fields. Command and response examples are shown throughout the
table. The ASCII to Hex conversion table below is for use with the command and response
table.

ASCII to Hex Conversion Table

Space