beautypg.com

Audio adjustment area, Audio output level area, Firmware upgrade – Extron Electronics FOX 500 DA6 User Guide User Manual

Page 26: Firmware upgrade -23, Remote control, cont’d

background image

FOX 500 DA6 • Remote Control

Remote Control, cont’d

3-22

FOX 500 DA6 • Remote Control

3-23

Audio Adjustment area

Audio Gain/Attenuation

slider —

Click and drag the Audio

Gain/Attenuation

slider control to select the input audio gain or

attenuation value, from -18 dB to +10 dB in 1.0 dB increments.

Audio Output Level area

Audio Output Level radio buttons —

Click either the

Consumer Level

(-10 dBV) or Professional Level (+4 dBu) radio

button to select the output audio level.

N

When you make an audio output level change, the setting

is changed in the receiver(s). The master receiver reports

the changes to the DA via the optional Optical 2 cable

connected betweeen the DA and the master receiver.

If your computer is connected to either of the DA's serial

ports, and the Optical 2 cable is not connected between the

master receiver and the DA in your system, the program

cannot report the output audio level in the control

program's Audio Adjustment area. You can change the

level, but the program cannot report the changes. The

program shows the

Set Consumer (or Professional)

level message to indicate that the output level command is

control only, not and indication (figure 3-7). The message

is displayed for approximately 1 second.

Figure 3-7 — Alternate Audio Adjustment area
indication

Firmware upgrade

Firmware can be upgraded via either of the unit's serial ports by

opening the Extron Firmware Loader utility from the Windows-

based control program.

N

When firmware upgrades are available, they are unique to

the unit; a DA firmware upgrade and a separate receiver

upgrade for the Rx unit.

You must connect directly to the unit to be updated.

Upload replacement firmware as follows:
1

.

Visit the Extron web site, www.extron.com, click the
Download Center

tab, and then click the Firmware link

(figure 3-8). Select the appropriate firmware file(s) to

download and copy it (them) to your computer. Note the

folder to which you save the firmware file(s).

Figure 3-8 — Location of firmware upgrade files

2

.

In the Windows Explorer or other file browser, double-click

the downloaded executable (*.exe) file(s) to self-extract the

firmware file(s).

3

.

Connect a Windows-based computer to either serial port

(rear panel Remote RS-232 or front panel Configuration)

of the unit to be updated. See chapter 2, "Installation and

Operation", for more details.

4

.

Start the FOX 500 Control Program. See "Starting the

program", on page 3-16.

5

.

Click Tools > Update Firmware. The Extron Firmware

Loader appears (figure 3-9).