beautypg.com

Remote control, cont’d – Extron Electronics FOX 500 DA6 User Guide User Manual

Page 21

background image

FOX 500 DA6 • Remote Control

Remote Control, cont’d

3-12

FOX 500 DA6 • Remote Control

3-13

Command

ASCII Command

(host to unit)

Response

(unit to host)

Additional description

Audio mute

Mute the audio

1Z

Amt1

]

Silence the r

eceiver's audio output.

Unmute the audio

0Z

Amt0

]

The r

eceiver outputs audio.

Show mute status

Z

X!]

Auto memory

Disable auto memory

55*0#

Img0

]

Enable auto memory

55*1#

Img1

]

Show auto memory status

55#

X!]

Auto image

Trigger auto image

55*2#

Img

]

Fr

ont panel lock (Executive mode)

Lock the fr

ont panel

1X

Exe1

]

Unlock the fr

ont panel

0X

Exe0

]

Show the panel lock status

X

X!]

Command/r

esponse table for SIS commands (continued)

Command/r

esponse table for SIS commands (continued)

Command

ASCII Command

(host to unit)

Response

(unit to host)

Additional description

Test patter

n

N

You

must

have

a

video

input

connected

and

fiber

cable

Optical

1

connected

between

the

DA

and

r

eceiver

for

the

r

eceiver

to

output

a

selected

test

pattern.

The

test

pattern

turns

off

if

the

input

signal

rate

is

changed

or

disconnected

or

if

power

is

r

emoved.

Output Color Bars

1J

Tst1

]

Set the r

eceiver to output the Color Bars test pattern.

Output grayscale

2J

Tst2

]

Set the r

eceiver to output the grayscale test pattern.

Output alt. pixels

3J

Tst3

]

Set the r

eceiver to output the alternating pixels test

pattern.

Test pattern of

f

0J

Tst0

]

Set the r

eceiver to output the input video (no test pattern

selected).

Show test pattern status

J

X1$]