FOX 500 DA6 • Remote Control

Remote Control

FOX 500 DA6 • Remote Control

3-2

3-3

The DA has two serial ports that can be connected to a host

device such as a computer running the HyperTerminal utility,

an RS-232 capable PDA, or a control system. These ports make

serial control of the DA and the connected receivers possible.

The serial ports are:
• The rear panel Remote RS-232 port on 3-pin captive screw

connectors

• The front panel Configuration (RS-232) port, a 2.5 mm

mini stereo jack

The protocol for all ports is as follows:
• 9600 baud

• no parity

• 8 data bits

• 1 stop bit

• no flow control

N

The rear panel Remote RS-232 port is active only if the

front panel Configuration port is not in use. If a front

panel configuration connection is made, the rear panel

Remote RS-232 port becomes inactive and the front panel

Configuration port is active.

N

Only one fiber optic cable, Optical 1, is required for

video, audio, and serial command transmission. But,

if you connect only one fiber optic cable, you do not

receive RS-232 communications from the controlled

device connected to the master receiver, and there is

reduced RS-232 command and Windows control program

functionality on the receiver. To receive responses

from the master receiver and for full functionality,

you must install both fiber optic cables between the

DA and the master receiver.

Rear Panel Remote RS-232 Ports

Function

Pin

TX

RX

Gnd

Transmit data
Receive data
Signal ground

Controlling

Device

Ground ( )
Receive (Rx)
Transmit (Tx)

Ground ( )

Receive (Rx)

Transmit (Tx)

Bidirectional

REMOTE

RS-232

ALARM

Tx Rx

1 2

Do not tin the wires!

Figure 3-1 — Remote connector pin assignments

Front Panel Configuration Port

N

The front panel configuration ports parallel the rear panel

Remote RS-232 ports. If a front panel configuration

connection is made, the rear panel Remote RS-232 port

becomes inactive and the front panel Configuration port is

active.

The optional 9-pin D to 2.5 mm mini jack TRS RS-232 cable,

part #70-335-01 (figure 3-2) can be used for connection to the

Configuration port.

6 feet

(1.8 m)

Part #

70-335-01

5

1

9

6

Sleeve (Gnd)

Ring

Tip

9-pin D

Connection

TRS Plug

Pin 2

Computer's RX line

Tip

Pin 3

Computer's TX line

Ring

Pin 5

Computer's signal ground

Sleeve

Figure 3-2 — Optional 9-pin TRS RS-232 cable

Simple Instruction Set Control

Host-to-interface communications

SIS commands consist of one or more characters per field. No

special characters are required to begin or end a command

character sequence. When a command is valid, the unit executes

the command and sends a response to the host device. All

responses from the unit to the host end with a carriage return

and a line feed (CR/LF = ]), which signals the end of the

response character string. A string is one or more characters.

Symbol definitions

Symbols (variables), defined on the next page, are used

throughout the "Unit-initiated messages" section and the

command/response table beginning on page 3-8. The symbols

represent variables in the unit-initiated messages and the

command/response table fields.