The input's audio level can be individually set via the master

receiver's front panel or RS-232 control. Refer to the FOX 500

Tx/Rx

manual and see chapter 3, "Remote Control" in this

manual.

e

RS-232 Over Fiber port — If you want the

FOX 500 to pass serial command signals to the

receiver(s) (for serial control of a projector, for

example), connect the host device to the DA via

the left three poles of this 5-pole captive screw

connector. See "Rear panel serial ports connection" on page

2-8 to wire this connector.

N

If you connect only one fiber optic cable (item

h

,

on the

next page), you do not receive reports from the controlled

device connected to the master receiver. To receive

responses from the controlled device, you must install two

fiber optic cables.

N

The FOX 500 can pass RS-232 commands and responses

at rates up to 38400 baud.

f

Remote RS-232 port —

For serial control of the

DA, connect a host device, such as a computer,

touch panel control, or RS-232 capable PDA, to the

DA via the left three poles of this 5-pole captive

screw connector.

See "Rear panel serial ports

connection" on page 2-8 to wire this connector.

See chapter 3, "Remote Control", for definitions of the SIS

commands (serial commands to control the DA via this

connector).

g

Alarm outputs port — For remote monitoring

of the status of fiber optic link 2 from the

master receiver, connect a locally-constructed

or furnished device to the DA via the right two

poles of this 5-pole captive screw connector.

When the DA does not detect a light link on fiber cable

Optical 2 (optional) of output 1, it shorts pin 1 and pin 2 of

this port together.

FOX 500 Tx DA6

OPTICAL

1

1

2

LINK

LINK

2

1 2*

*

NOT USED

3

1 2*

*

NOT USED

4

1 2*

*

NOT USED

5

1 2*

*

NOT USED

6

1 2*

*

NOT USED

8

8

8

8

8

8

Figure 2-5 — DA’s connectors, right side

h

Fiber optic connectors and LED

W

These units output continuous invisible light,

which may be harmful and dangerous to the eyes;

use with caution. For additional safety, plug the

attached dust caps into the optical transceivers

when the fiber optic cable is unplugged.

N

Singlemode and multimode devices are not

interchangeable. Ensure that you connect receiving

devices that are compatible with the DA.

N

Ensure that you use the proper fiber cable for your

DA/receiver pair. Typically, singlemode fiber has a yellow

jacket and multimode cable has an orange jacket.

N

Only one fiber optic cable, Optical 1, is required for

video, audio, and serial command transmission. But,

if you connect only one fiber optic cable, you do not

receive RS-232 communications from the controlled

device connected to the master receiver, and there is

reduced RS-232 command and Windows control program

functionality on the receiver. To receive responses

from the master receiver and for full functionality,

you must install both fiber optic cables between the

DA and the master receiver.

Optical 1

— For all one-way video, audio,

and serial communications from the DA to

the receiver, connect a fiber optic cable to the

Optical 1 LC connector.

Connect the free end of this fiber optic cable to

the Optical 1 connector on the receiver

or other

compatible Extron device

.

Optical 2

— For all one-way serial

communications from the master receiver

to the DA, connect a fiber optic cable to the

Optical 2 LC connector.

Connect the free end of this fiber optic cable

to the Optical 2 connector on the

receiver

connected to DA output 1 or to any other

compatible device

.

N

Optical 2 is functional only for output 1.

Link 1 and Link 2 LEDs

— When lit, the link

is active (light is received).

N

The Link 1 and Link 2 LEDs are present only for output 1.