beautypg.com

7 rebuilding the raid, Exiting the intel, Rapid storage technology utility -32 – Asus RS320Q-E7/RS12 User Manual

Page 126: Rebuilding the raid -32, Rebuilding the raid with other non-raid disk, 6 exiting the intel, Rapid storage technology utility

background image

6-32

Chapter 6: RAID configuration

Select a destination disk with the same size as the original hard disk.

6.3.7

Rebuilding the RAID

This option is only for the RAID 1 set.

Rebuilding the RAID with other non-RAID disk

If any of the SATA hard disk drives included in the RAID 1 array failed, the system displays

the status of the RAID volume as “Degraded” during POST. You can rebuild the RAID array

with other installed non-RAID disks.
To rebuild the RAID with other non-RAID disk:

1.

At the prompt, press + to enter the Intel Rapid Storage Technology option

ROM utility.

2.

If there is a non-RAID SATA Hard Disk available, the utility will prompt to rebuild the

RAID. Press , and then use up/down arrow keys to select the destination disk

or press to exit.

6.3.6

Exiting the Intel

®

Rapid Storage Technology utility

To exit the utility:
1.

From the utility main menu, select 4. Exit, and then press . The following

warning message appears.

2.

Press to exit or press to return to the utility main menu.

Are you sure you want to exit? (Y/N):

[

CONFIRM EXIT

]

[

DEGRADED VOLUME DETECTED

]

[↑↓]-Previous/Next [ENTER]-Select [ESC]-Exit

"Degraded" volume and disk available for rebuilding detected. Selecting

a disk initiates a rebuild. Rebuild completes in the operating system.

Select the port of destination disk for rebuilding (ESC to exit):

Port Drive Model Serial # Size

X XXXXXXXXXXX XXXXXXXX XX.XGB