beautypg.com

5 checking the drives for data consistency, Checking the drives for data consistency -18, Using the check consistency command – Asus RS320Q-E7/RS12 User Manual

Page 112

background image

6-18

Chapter 6: RAID configuration

6.2.5

Checking the drives for data consistency

You can check and verify the accuracy of data redundancy in the selected virtual drive. The

utility can automatically detect and/or detect and correct any differences in data redundancy

depending on the selected option in the Objects > Adapter menu.

The Check Consistency command is available only for virtual drives included in a RAID 1

or RAID 10 set.

Using the Check Consistency Command

To check data consistency using the Check Consistency command

1.

From the Management Menu, select Check Consistency, and then press .

2.

The screen displays the available RAID set(s) and prompts you to select the virtual

drive to check. Press to select the virtual drive from the Virtual Drive sub-

menu, and then press .

Management Menu

Configure

Initialize

Objects

Rebuild

Check Consistency

CC Of VD(s)

LSI Software RAID Configuration Utility Ver C.05 Feb 17, 2012

BIOS Version A.10.09231523R

Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

Management Menu

Configure

Initialize

Objects

Rebuild

Check Consistency

Select VD

Virtual Drive(s) Configured

LD RAID Size #Stripes StripSz Status

0 1 148.580GB 2 64 KB ONLINE

Virtual Drives

Virtual Drive 0

LSI Software RAID Configuration Utility Ver C.05 Feb 17, 2012

BIOS Version A.10.09231523R

SPACE-(De)Select, F10-Check Consistency