6-39

6.3.8.

Rebuilding.the.RAID

This option is only for the RAID 1, RAID 5 and RAID 10 level.

Rebuilding the RAID with other non-RAID disk:

1. If one member of physical SATA Hard disk within the array is off-line or failed,

the status of array will become to be degraded from normal. The following

displays as:

2. Press to enter the Intel Matrix Storage Manager RAID configuration

utility after POST.

3. If there is available Non-RAID SATA Hard Disk, the utility will prompt

the windows for rebuilding the RAID. Press to select the port of

destination disk for rebuilding or press to exit

The size of destination disk for rebuilding should be the same or bigger as the

original hard disk.