Com2 console redirection [disabled, Console redirection settings – Asus ESC2000 G2 User Manual
Page 112
4-36
Chapter 4: BIOS setup
Data Bits [8]
Configuration options: [7] [8]
Parity [None]
A parity bit can be sent with the data bits to detect some transmission errors.
[Mark] and [Space] parity do not allow for error detection.
[None]
No parity bit
[Even]
Parity bit is 0 if the num of 1’s in the data bits is even
[Odd]
Parity bit is 0 if num of 1’s in the data bits is odd
[Mark]
Parity bit is always 1
[Space]
Parity bit is always 0
Stop Bits [1]
Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning.)
The standard setting is 1 stop bit. Communication with slow devices may require more
than 1 stop bit.
Configuration options: [1] [2]
Flow Control [VT100]
Microsoft Windows Emergency Management Services (EMS) allow for remote
management of a Windows Server OS through a serial port.
Configuration options: [VT100] [Hardware RTS/CTS] [Software Xon/Xoff]
Recorder Mode [Disabled]
With this mode enabled, only text will be sent. This is to capture Terminal data.
Configuration options: [Disabled] [Enabled]
Recorder 100x31 [Disabled]
This item allows you to enable or disable extended terminal resolution.
Configuration options: [Disabled] [Enabled]
Legacy OS Redirction Resolution [80x24]
This item configures the number of rows and columns supported on legacy OS.
Configuration options: [80x24] [80x25]
COM2
Console Redirection [Disabled]
Enables or disables the console redirection feature.
Configuration options: [Disabled] [Enabled]
Console Redirection Settings
Please refer to the description of the Console Redirection Settings item under COM1 for
details.