20a analog microdlynx, Non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 20A Analog MicroDLynx User Manual
Page 5: Feature specifications (cont.)

GE
Data Sheet
20A Analog MicroDLynx
TM
: Non-Isolated DC-DC Power Modules
3Vdc –14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current
April 24, 2013
©2012 General Electric Company. All rights reserved.
Page 5
Feature Specifications (cont.)
Parameter
Device
Symbol
Min
Typ
Max
Units
Turn-On Delay and Rise Times
(V
IN
=V
IN, nom
, I
O
=I
O, max ,
V
O
to within ±1% of steady state)
Case 1: On/Off input is enabled and then input power is
applied (delay from instant at which V
IN
= V
IN, min
until V
o
=
10% of V
o, set
)
All
Tdelay
―
1.2
―
msec
Case 2: Input power is applied for at least one second and
then the On/Off input is enabled (delay from instant at
which Von/Off is enabled until V
o
= 10% of V
o, set
)
All
Tdelay
―
0.8
―
msec
Output voltage Rise time (time for V
o
to rise from
10% of Vo, set to 90% of Vo, set)
All
Trise
―
2.7
―
msec
Output voltage overshoot (T
A
= 25
o
C
V
IN
= V
IN, min
to V
IN, max
,I
O
= I
O, min
to I
O, max
)
With or without maximum external capacitance
3.0
% V
O, set
Over Temperature Protection
(See Thermal Considerations section)
All
T
ref
120
°C
Tracking Accuracy (Power-Up: 2V/ms)
All
V
SEQ
–V
o
100
mV
(Power-Down: 2V/ms)
All
V
SEQ
–V
o
100
mV
(V
IN, min
to V
IN, max
; I
O, min
to I
O, max
V
SEQ
< V
o
)
Input Undervoltage Lockout
Turn-on Threshold
All
3.25
Vdc
Turn-off Threshold
All
2.6
Vdc
Hysteresis
All
0.25
Vdc
Resolution of Adjustable Input Under Voltage Threshold
All
500
mV
PGOOD (Power Good)
Signal Interface Open Drain, V
supply
5VDC
Overvoltage threshold for PGOOD ON
All
108
%V
O, set
Overvoltage threshold for PGOOD OFF
All
105
%V
O, set
Undervoltage threshold for PGOOD ON
All
110
%V
O, set
Undervoltage threshold for PGOOD OFF
All
90
%V
O, set
Pulldown resistance of PGOOD pin
All
50
Sink current capability into PGOOD pin
All
5
mA
* Over temperature Warning – Warning may not activate before alarm and unit may shutdown before warning