Data sheet, Absolute maximum ratings, Electrical specifications – GE Industrial Solutions SW-SC001-003 Series User Manual
Page 2
GE
Data Sheet
SW/SC001/003 Series DC-DC Power Module
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
October 14, 2013
©2013 General Electric Company. All rights reserved.
Page 2
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
Input Voltage (Continuous)
SW
V
IN
-0.3
80
Vdc
SC
V
IN
-0.3
50
Transient (100ms)
All
V
IN, trans
-0.3
100
Vdc
Operating Ambient Temperature
All
T
A
-40
85
°C
(see Thermal Considerations section)
Storage Temperature
All
T
stg
-55
125
°C
I/O Isolation Voltage (100% factory Hi-Pot tested)
All
2250
Vdc
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Operating Input Voltage
SW
V
IN
36
54
75
Vdc
SC
V
IN
18
27
36
Vdc
Maximum Input Current (V
IN
=0V to 75V, I
O
=I
O, max
)
SW
I
IN,max
0.6
Adc
(V
IN
=0V to 36V, I
O
=I
O, max
)
SC
I
IN,max
1.2
Adc
Inrush Transient
All
I
2
t
0.05
A
2
s
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; V
IN
=0V to 75V, I
O
=
I
Omax
; see Test configuration section)
All
30
mAp-p
Input Ripple Rejection (120Hz)
All
50
dB
EMC, EN55022
See EMC Considerations section
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being part of
complex power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety
and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 3A
(see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input
current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.