Data sheet, Absolute maximum ratings, Electrical specifications – GE Industrial Solutions EVK011A0B Series (Eighth-Brick) User Manual
Page 2
![background image](/manuals/295105/2/background.png)
GE
Data Sheet
EVK011A0B Series (Eighth-Brick) DC-DC Converter Power Modules
36–60Vdc Input; 12.0Vdc Output; 11A Output Current
May 15, 2013
©2012 General Electric Company. All rights reserved.
Page 2
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
Input Voltage
Continuous All
V
IN
-0.3 60 V
dc
Transient (≤10 ms)
All
V
IN,trans
-0.3 75 V
dc
Operating Ambient Temperature
All
T
A
-40 85 °C
(see
Thermal
Considerations
section)
Storage Temperature
All
T
stg
-55 125 °C
I/O Isolation voltage (100% factory Hi-Pot tested)
All
2250 V
dc
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Operating Input Voltage
All
V
IN
36 48 60 V
dc
Maximum Input Current
All I
IN,max
4.0 4.4 A
dc
(V
IN
= V
IN, min
to V
IN, max
, I
O
=I
O, max
)
Input No Load Current
All I
IN,No load
75 mA
(V
IN
= V
IN, nom
, I
O
= 0, module enabled)
Input Stand-by Current
All I
IN,stand-by
20 mA
(V
IN
= V
IN, nom
, module disabled)
Inrush Transient
All
I
2
t
0.5 A
2
s
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
IN, min
to V
IN,
max,
I
O
= I
Omax
; See Test configuration section)
All
20
mA
p-p
Input Ripple Rejection (120Hz)
All
50
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part
of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included, however, to achieve
maximum safety and system protection, always use an input line fuse. The safety agencies require a time-delay fuse with a
maximum rating of 8 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy
and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet
for further information.