Picotlynx, 3a: non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions PicoTLynx 3A User Manual
Page 2: Absolute maximum ratings, Electrical specifications

GE
Data Sheet
PicoTLynx
TM
3A: Non-Isolated DC-DC Power Modules
2.4Vdc –5.5Vdc input; 0.6Vdc to 3.63Vdc output; 3A Output Current
September 11, 2013
©2013 General Electric Company. All rights reserved.
Page 2
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
Input Voltage
All
V
IN
-0.3 6 Vdc
Continuous
Sequencing Voltage
APTH
V
SEQ
-0.3 V
iN, Max
Vdc
Operating Ambient Temperature
All
T
A
-40 85 °C
(see Thermal Considerations section)
Storage Temperature
All
T
stg
-55 125 °C
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Operating Input Voltage
All
V
IN
2.4 ⎯
5.5 Vdc
Maximum Input Current
All
I
IN,max
3.5 Adc
(V
IN
=2.4V to 5.5V, I
O
=I
O, max
)
Input No Load Current
V
O,set
= 0.6 Vdc
I
IN,No load
26
mA
(V
IN
= 5.0Vdc, I
O
= 0, module enabled)
V
O,set
= 3.3Vdc
I
IN,No load
75
mA
Input Stand-by Current
All
I
IN,stand-by
2.1
mA
(V
IN
= 5.0Vdc, module disabled)
Inrush Transient
All
I
2
t
1
A
2
s
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
IN
=0 to
5.5V
,
I
O
= I
Omax
; See Test Configurations)
All
25
mAp-p
Input Ripple Rejection (120Hz)
All
40
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of
sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum
safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating
of 5A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc
input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further
information.