beautypg.com

SENA PS210W User Manual

Page 46

background image

46

or when no data transfer activity is found through the serial port for certain amount of time, which

is “Inactivity timeout” (See 3) Parameters for details on Inactivity timeout). All the data remained in

the serial port buffer will be cleared when it is disconnected.

Connection request from remote host

All the incoming TCP connection requests will be rejected in TCP client mode.

3) Parameters

TCP listening port

This is the TCP port number through which a remote host can connect a TCP session, and, send

and receive data. Incoming connection request(s) to the ports other than TCP Listening Port will

be rejected. The Pro Series does restrict the port number from 1024 to 65535 and if it is set as 0

only outgoing connection is permitted. (TCP server mode)

User authentication

If the User authentication option is enabled, the user can access the port after entering the correct

user ID and password. Please refer to the section 5.9 User administration for details of user

management.

Telnet protocol

In TCP mode, Pro Series supports Telnet Com Port Control Option (RFC2217 compliant) so that

user can control serial parameters like baud rate, data bits and flow control option using his local

RFC2217-compliant Telnet client program. (Please refer to section 4.2.6 Serial port parameters

for more detail information about serial parameters)

Usually this option is used with the RFC2217-compliant COM port redirector so that user can

control parameters of serial ports of Pro Series using his serial port application program.

For this purpose, SENA OEM version of Serial/IP from Tactical Software, LLC is bundled with Pro

Series. Please refer to documentations of Serial/IP for more detail information about using the

COM port redirector. (Please refer to section Appendix 5. Using Pro Series with Serial/IP for more

detail information)

Max. allowed connection

The Pro Series supports up to 8 multiple connections from external host(s) to the serial port. If

there are remote host connections by the remote host list configuration already, possible number

of connection will be reduced (Max. allowed connection - remote host(s) connected already). For

example, if user set Max. allowed connection as 8 and if there are 3 connections from Pro Series

to remote hosts, which are configured in the remote host list, then maximum number of

connection from external hosts to a serial port will be reduced to 5. For more detailed information

for remote host list configuration, please refer to 4.2.4. Remote host configuration section.